OVERVIEW
Air Burners’ PGF-100 is a revolutionary new method for eliminating wood and other vegetative waste, as well as clean construction debris. At the core of the system is Air Burners’ patented FireBox technology which has been tested and approved by regulatory agencies around the globe. The PG FireBox can eliminate up to eight tons per hour [7.3 mt/h] of waste material while simultaneously producing up to 100 kW of clean, emission-free energy without the use of supplemental fossil fuels.
In addition, the PG FireBox does not require any of the costly and emissions-intensive pre-processing (grinding/chipping/sorting) of fuel required by conventional biomass power generating systems. The PG FireBox consumes whole logs, limited only by the length of the FireBox in the system (generally 20 ft [6 m]). The volume of the waste material is reduced by approximately 98%, leaving only a small quantity of ash and BioChar that can be repurposed for agricultural or other uses.
A portion of the ‘waste’ heat in the exhaust from the FireBox is captured and directed to a heat exchanger to produce hot water (300° F [150° C] or less), which in turn supplies an Organic Rankine Cycle (ORC) power generating unit. The ORC utilizes a non-ozone-depleting organic working fluid in a ‘reverse refrigeration process’ where the thermal energy input to the system is converted to electrical energy by driving an asynchronous (induction) generator. The system is typically connected to the local electrical grid in a ‘Net Metering’ arrangement like rooftop solar (depending on local regulations) where either some or all of the energy is consumed on site and any excess energy produced is sold back to the utility.
Aside from the electrical grid connection, only a cooling source is required at the site. This can be a portable air blast cooler supplied by Air Burners or local water cooling. Local water cooling can include a river or lake. The cooling water is completely isolated from the PGF working fluids and none of the water is consumed. The local cooling water returns to the source unchanged except for a small temperature rise.
Product Specs

Specifications for Power Generation module
- POWER REQUIREMENTS
- 460 VAC/60 Hz/3φ or 400 VAC/50 Hz/3φ, 225 A Service
- POWER FACTOR
- Load and site-dependent (0.9 – 1.0)
- POWER GENERATION MODULE
- Fully-Integrated Organic Rankine Cycle (ORC) Power Module with 100 kW
Asynchronous Generator - ORC WORKING FLUID
- Honeywell Genetron 245fa (Non-ozone-depleting)
- SAFETY SYSTEMS
- Electrical Grid Protection, Over-Temperature, Over-Pressure
- CONTROL SYSTEM
- PLC-Based with Touch-Screen
- REMOTE MONITORING
- Internet-based monitoring of operations
- TRANSPORTATION AND SETUP
- Ships in containers; Ready for immediate use after simple hood installation
and grid connection; Padeyes provided for crane lifting. Full skid base
facilitates final positioning - OPTIONAL COOLING WATER (CW)
- 325 gpm [20.5 l/s], 70° F [20° C] The system comes standard with the air blast
cooling but if cooling water is available it will typically lower the overall
cost of the system. Contact the factory for more information. - CW INTERFACE
- 4″ Nominal, 150 lb-Class ANSI Flanges
- INDUCTION FAN
- PLC-Controlled; Variable Speed
- HOT WATER (HW) PUMP
- PLC-Controlled; Variable Speed
- HW SYSTEM WORKING FLUID
- Ethylene-Glycol/Water Mix
- CONSTRUCTION
- Steel WF beam and square tubing construction with full-length skid plate;
Epoxy-paint - APPROX. WEIGHT
- 39,000 lbs [17700 kg]
- DIMENSIONS
- L x W x H 33.5 ft x 7.5 ft x 10.5 ft [10.2 m x 2.3 m x 3.2 m]
Specifications for Firebox Module
- AIR CURTAIN FAN POWER
- 30 hp [22 kW] Electric Motor VFD-Controlled
- BURN CONTAINER (FIREBOX)
- 4″ [102 mm] thick refractory panels filled with proprietary thermal ceramic
material. Two full-height rear doors, two ignition holes - SAFETY SYSTEMS
- Fully integrated with PGF controller
- INSTRUMENT PANEL
- Touch-screen control from PGF Control Room
- AIR CURTAIN FAN MOTOR CONTROL SYSTEM
- PLC-Based; Speed selection fully integrated with system controller
- AIR SUPPLY
- Custom Heavy Duty Fan
- TRANSPORTATION AND SETUP
- Shipped fully assembled and tested, requires only connection of the
three-phase motor power to the PG Module power distribution panel - WASTE MATERIAL ELIMINATION RATE
- Up to 8 tons per hour [7.3 mt/h]
- FIREBOX MODULE WEIGHT
- 36,000 lbs [16,300 kg]
- OVERALL DIMENSIONS
- L x W x H 30′ x 7′ 5″ x 8′ 5″ [9.1 m x 2.3 m x 2.6 m]
- FIREBOX INSIDE DIMENSIONS
- L x W x H 19′ 8″ x 5′ 0″ x 7′ 1″ [6.0 m x 1.5 m x 2.2 m]
Specifications for AIR BURNERS AIR BLAST COOLER FOR CONDENSING WATER
- AIR BURNERS AIR BLAST COOLER FOR CONDENSING WATER
- 8,100 lbs [3680 kg]
- DIMENSIONS
- L x W x H 30′ 4″ x 7′ 6″ x 8′ 4″ [9.2 m x 2.3 m x 2.5 m]