1
Section 1 · Questions 1–20
The Basics
20 questions
The Basics
1
What is an Air Curtain Incinerator?
2
How does an Air Curtain Incinerator work?
3
Why would I use an Air Curtain Incinerator instead of hauling, grinding, chipping, or landfilling my debris?
4
How much money can an Air Curtain Incinerator save me?
5
How much material can an Air Curtain Incinerator process per hour, day, week, and month?
6
What types of material can I burn in an Air Curtain Incinerator?
7
Can an Air Curtain Incinerator burn freshly cut green trees?
Yes, ACIs can process freshly cut green trees. The facts are 90% of the time the material burned are freshly cut trees from land clearing projects. While it is true that high moisture absorbs heat and can lower throughput and increase visible smoke, particularly during startup. But once you get the fire to operational temperature the smoke clears in seconds. I would say the average time it takes to clear smoke is about 26 seconds. Combining wet loads with suitable drier material and maintaining a hot fire greatly improves results.
8
How smokeless is an Air Curtain Incinerator?
9
Is an Air Curtain Incinerator the same thing as an Air Curtain Burner?
10
Is an Air Curtain Incinerator considered open burning?
11
What is the difference between an Air Curtain Incinerator and simply burning a debris pile?
12
What does the “air curtain” actually do?
13
Why does the high-velocity air reduce smoke?
14
How hot does an Air Curtain Incinerator burn?
15
How quickly does it reach operating temperature?
16
What happens inside the burn chamber?
17
Why does an Air Curtain Incinerator burn wood faster than an open pile?
18
How much does the original debris volume decrease after burning?
19
How much ash remains?
20
What are the primary advantages of air-curtain burning?
2
Section 2 · Questions 21–48
What You Can and Can't Burn
28 questions
What You Can and Can't Burn
21
What materials are legally and technically suitable for burning?
22
Can I burn trees?
23
Can I burn whole trees?
24
Can I burn tree trunks?
25
Can I burn large logs?
26
Can I burn branches and brush?
27
Can I burn stumps?
28
Can I burn root balls?
29
Can I burn storm-damaged trees?
30
Can I burn hurricane debris?
31
Can I burn tornado debris?
32
Can I burn forestry debris?
33
Can I burn land-clearing debris?
34
Can I burn orchard or agricultural wood waste?
35
Can I burn clean pallets?
36
Can I burn untreated dimensional lumber?
37
Can I burn demolition wood?
38
Can I burn wet wood?
39
Can I burn wood immediately after it is cut?
40
How does moisture content affect production?
41
What happens when I burn extremely wet material?
42
Does muddy material or dirt-covered root material affect burning?
43
What materials should never be placed in the machine?
44
Can treated lumber be burned?
45
Can painted wood be burned?
46
Can garbage or municipal solid waste be burned?
47
Can plastics, tires, chemicals, or hazardous materials be burned?
48
Do prohibited materials differ by state or permit?
3
Section 3 · Questions 49–70
Production and Throughput
22 questions
Production and Throughput
49
How many tons per hour can the machine burn?
50
How many cubic yards per hour can it process?
51
How many acres of land-clearing debris can I process per day?
52
How many cubic yards can it process in a 10-hour workday?
53
How many cubic yards can it process in a month?
54
How many truckloads of debris does that represent?
55
Is the advertised burn rate a maximum or a realistic working production rate?
56
What conditions determine actual production?
57
How much does green wood reduce production?
58
How much does material size affect production?
59
Do large logs burn slower than brush?
60
How do stumps affect production?
61
Does continuously feeding the machine increase production?
62
How often should material be loaded?
63
Can the machine operate continuously throughout the workday?
64
Can it operate 24 hours a day?
65
How long does it take to burn down at the end of a shift?
66
How much material can Burn Debris’s fleet process during a large disaster response?
67
How do I calculate the number of machines required for my project?
68
If I tell you my debris volume and deadline, can you calculate the machine requirement?
69
What machine would I need to process a specific tonnage or cubic-yard target?
70
When does it make sense to operate multiple machines simultaneously?
4
Section 4 · Questions 71–93
Costs and Economics
23 questions
Costs and Economics
71
What does it cost per ton to dispose of debris with an Air Curtain Incinerator?
72
What does it cost per cubic yard?
73
How does the cost compare with hauling the debris away?
74
How does it compare with grinding?
75
How does it compare with chipping?
76
How does it compare with landfill or tipping fees?
77
How does it compare with tub grinding?
78
How does it compare with horizontal grinding?
79
Is burning or grinding faster?
80
What happens to the economics when the disposal facility is far from the project?
81
How much trucking can I eliminate?
82
How many trucks can one Air Curtain Incinerator replace?
83
How much can I save in trucking costs?
84
How much can I save in landfill or tipping fees?
85
What is the cost of diesel per operating hour?
86
What is the total operating cost per engine hour?
87
What labor is required?
88
What equipment is required in addition to the burner?
89
What is my estimated total project cost?
90
What is my estimated savings for the entire project?
91
At what project size does an Air Curtain Incinerator become economical?
92
When does purchasing become less expensive than renting?
93
What is the potential return on investment from purchasing a machine?
5
Section 5 · Questions 94–155
Air Burner 300 Series: S327 and S330 Air Curtain Incinerator
62 questions
Air Burner 300 Series: S327 and S330 Air Curtain Incinerator
94
What engine and drive coupling configuration is installed on the S327 and S330 FireBox?
A HATZ 4H50-TIC Tier 4 Final diesel engine equipped with a fluid coupling (automatic clutch) and direct coupling mechanical drive. At times you will find them with Kubota engines. We have used John Deere, Perkins, and Cummins also. New from the factory now they are using Hatz.
95
What is the overall length, width, and height of the S330 FireBox?
The overall size of the S330 is 40 ft 4 in length x 11 ft 10 in width x 9 ft 6 in height.
96
What are the internal firebox (burn chamber) dimensions of the S330 FireBox?
The internal firebox dimensions of the S330 are 30 ft 2 in length x 8 ft 5 in width x 8 ft 1 in height.
97
What is the total approximate operating weight of the S330 FireBox?
Approximately 59,000 lb. (26,760 kg).
98
What is the average throughput capacity of the S330 FireBox?
Approximately 11 to 13 tons per hour.
99
What are the overall dimensions (L x W x H) of the S327 FireBox?
The overall size of the S327 is 37 ft 4 in length x 11 ft 10 in width x 9 ft 6 in height.
100
What are the internal firebox (burn chamber) dimensions of the S327 FireBox?
The internal firebox dimensions of the S327 are 27 ft 2 in length x 8 ft 5 in width x 8 ft 1 in height.
101
What is the total approximate weight of the S327 FireBox?
Approximately 54,600 lb. (24,800 kg).
102
What is the average throughput capacity of the S327 FireBox?
Approximately 9 to 11 tons per hour.
103
What is the average diesel fuel consumption rate for the S327 and S330 FireBox models?
Approximately 3.0 gallons per hour at average operating RPM.
104
What is the minimum diesel fuel tank capacity on the S327 and S330 FireBox?
Minimum 110 gallons (416 Liters).
105
What electric motor option and variable frequency drive configuration are available for the S327 and S330 FireBox?
A heavy-duty 3-phase electric motor equipped with an enclosed pre-programmed variable frequency speed controller (VFD), accepting Three Phase 480V (50Hz or 60Hz), or optional 400V/415V.
106
What type of base frame structure is used on the S327 and S330 FireBox?
A heavy skid-type base frame open to the earthen soil designed for dragging across the ground on site.
107
How much do each of the rear access and clean-out doors weigh on the S327 and S330 FireBox?
Each refractory-lined rear door weighs approximately 2,000 lb.
108
What terrain slope limitation must be strictly observed before opening the 2,000 lb rear doors on the S327 and S330 FireBox?
The rear doors should not be opened if the FireBox is inclined on any axis more than 5 degrees.
109
Why must dirt be shoveled around the inside bottom rails of the S327 and S330 FireBox during site placement?
To seal openings under the skids caused by uneven ground terrain, preventing heat and smoke from escaping and stopping hot gas from reaching the forward equipment deck.
110
Why is digging an earthen pit in the center of the S327 and S330 FireBox strictly prohibited?
Digging a pit makes it difficult to seal the unit, pit walls deteriorate during burning, and escaping heat under the engine deck can create severe deck hazards and voids the factory warranty.
111
On what surface types is it strictly prohibited to operate the S327 and S330 FireBox?
Combustibles (dry grass, peat moss), concrete pads, asphalt, gravel, or crushed stone surfaces.
112
Why will operating the S327 or S330 FireBox on a concrete pad or gravel cause an explosion hazard?
Trapped moisture inside the concrete or rock vaporizes rapidly from intense downward heat, generating extreme internal pressure that causes concrete or stones to explode violently.
113
Why must the HATZ diesel engine on the S327 and S330 FireBox be warmed up and then shut down prior to lighting the fire?
Because the fluid coupling spins the fan even at idle, which creates air movement that makes lighting difficult and can blow out a newly lit fire.
114
What is the base engine idle speed on the S327 and S330 FireBox?
900 RPM.
115
What is the warm-up and cool-down throttle setpoint on the S327 and S330 FireBox?
1400 RPM.
116
What is the Operating Low engine RPM setting specifically for the S327 FireBox?
2200 RPM.
117
What is the Operating Low engine RPM setting specifically for the S330 FireBox?
2300 RPM.
118
What is the Operating High (maximum operating) engine RPM setting specifically for the S327 FireBox?
2500 RPM.
119
What is the Operating High (maximum operating) engine RPM setting specifically for the S330 FireBox?
2600 RPM.
120
How does the fluid coupling behave when the ignition switch is turned to OFF on the S327 and S330 FireBox?
The air fan free-wheels through the fluid coupling and gradually spins to a stop without harming the engine.
121
What function does turning the ignition key to the 'Auto' position have on the S327 and S330 FireBox?
The 'Auto' key position is non-functional and not used for the HATZ diesel engine.
122
What must be done before performing any welding repairs on the S327 and S330 FireBox?
Disconnect the negative battery cable and physically remove the Electronic Control Module (ECM) from the engine brackets to prevent destroying the computer controller.
123
Why is loading over the air manifold recommended for the S327 and S330 FireBox?
Loading over the manifold is the safest side for personnel from escaping embers and reduces the risk of excavator implements accidentally striking and damaging the manifold.
124
How is a cold start fire ignited inside the S327 and S330 FireBox?
From the bottom through the dedicated side access doors in the panels on the manifold side of the machine, using a propane torch or oil-soaked rags on poles.
125
How much diesel fuel is sprayed over the initial wood bed when cold lighting the S327 or S330 FireBox?
Approximately 10 gallons spread across the initial half-full load of dry wood, concentrating near the side lighting holes and back wall.
126
How does the operator 'fan' the young fire during startup in the S327 FireBox?
By increasing engine speed from 1400 RPM up to 2500 RPM for 3 to 8 minutes, then throttling back to 1400 RPM to spread the flames without blowing the fire out.
127
How does the operator 'fan' the young fire during startup in the S330 FireBox?
By increasing engine speed from 1400 RPM up to 2600 RPM for 3 to 8 minutes, then throttling back to 1400 RPM to spread the flames without blowing the fire out.
128
What load height restriction applies when burning wooden pallets in the S327 and S330 FireBox?
Do NOT load higher than approximately 3/4 of the firebox height, as spent pallets burn intensely hot and will warp or destroy the air manifold.
129
When burning clean logs and wood debris, what is the maximum load level inside the S327 and S330 FireBox?
Just below the bottom of the air manifold nozzles; loading higher breaks the air curtain and causes smoke emissions.
130
When is the best time to load heavy tree stumps into the S327 and S330 FireBox?
After the first hour of burning once the base fire has achieved full operating temperature.
131
How far in advance of site shutdown must wood waste loading cease on the S327 and S330 FireBox?
Loading should stop 1 to 2 hours before planned shutdown.
132
What flame clearance distance to the manifold is required before shutting down the engine on the S327 and S330 FireBox?
DO NOT shut off the engine or airflow while there are still flames within 24 inches of the manifold, as radiant heat will warp the manifold assembly.
133
To what residual bed depth must the fire burn down before the engine can be turned off on the S327 and S330 FireBox?
When the fire has burned down to about 1 or 2 feet and no flames are visible near the manifold.
134
Why must water never be sprayed onto the interior walls of the S327 and S330 FireBox during shutdown?
Cold water sprayed onto hot refractory ceramic panels causes thermal shock cracking and severe panel deterioration.
135
What is the maximum permissible ash depth inside the S327 and S330 FireBox before cleanout is mandatory?
No more than 3 feet of ash (which represents approximately 20 hours of burning operations).
136
Why does operating efficiency drop when ash depth exceeds 3 feet in the S327 and S330 FireBox?
Excess ash reduces combustion chamber volume, impairs internal circular airflow, and risks unburned embers being blown out of the box.
137
How is daily ash cleanout performed on the S327 and S330 FireBox when preserving an ember bed for a hot restart?
By opening the rear doors and scooping out 1 or 2 scoops of ash with an excavator or specialized Air Burners ash rake, leaving a bed of glowing coals. When you cover with dirt at the end of the day the coals will remain hot until the next day or longer.
138
What dragging procedure is used to empty the entire ash bed from the S327 and S330 FireBox at the end of a job?
Open the rear doors, cover the ash bed with a thin layer of dirt to control dust, attach certified cables to the front pull block or pad eyes, and drag the skid forward. Be sure to secure the doors wide open or you will break them.
139
What safety rule applies to walking inside the S327 or S330 FireBox during dragging operations?
NEVER walk or stand inside the FireBox while it is being towed or dragged; dirt buildup under skids can lift and dislodge 2,000 lb ir heavier panels onto personnel.
140
How many lifting pad eyes are equipped on the S327 and S330 FireBox for crane handling?
Four (4) designated lifting pad eyes (two on each side) marked with yellow 'Lifting Point' decals with up-arrows.
141
What safety rules must be followed when utilizing the observation ladder on the S327 and S330 FireBox?
Only authorized personnel wearing PPE may use the ladder, they must maintain a firm grip on the handle, and they must never step beyond the top ladder rung.
142
What model and size flexible drive coupling is installed between the engine and air fan on the S327 and S330 FireBox?
Dodge Raptor Coupling Size E30 (Air Burners Part Number 5000-2120).
143
What is the required hub gap measurement 'A' for the Dodge Raptor E30 coupling on the S327 and S330 FireBox?
2.55 inches (65 mm).
144
What is the maximum allowable angular misalignment value 'C' for the Dodge Raptor E30 coupling on the S327 and S330 FireBox?
0.284 inches (7.2 mm).
145
What is the maximum allowable parallel misalignment value 'D' for the Dodge Raptor E30 coupling on the S327 and S330 FireBox?
0.188 inches (4.8 mm).
146
What tightening torque is specified for the 3/8-inch element flange bolts on the Dodge Raptor E30 coupling of the S327 and S330 FireBox?
42 ft-lbs (502 in-lbs / 57 N�m).
147
Can the Dodge Raptor element bolts be reused after disassembly on the S327 and S330 FireBox?
No, bolts should be used only one time because they feature factory pre-applied thread-locking patches.
148
How is shaft alignment corrected if the Dodge Raptor E30 coupling on the S327 and S330 FireBox exceeds tolerance?
By adjusting the four (4) elastomeric engine isolators (motor mounts) beneath the engine base.
149
What is the lubrication interval and grease amount for the air fan bearings on the S327 and S330 FireBox?
Relubricate both inside and outside fan bearings every 2,100 hours of runtime with 12.5 g (0.44 oz.) of SKF LGMT 3IN/18 grease.
150
What is the lubrication interval and grease amount for the fluid coupling bearing on the S327 and S330 FireBox?
Relubricate every 120 hours of runtime with 10 g (0.35 oz.) of SKF LGMT 3IN/18 grease.
151
What service interval is required for factory servicing of the fluid coupling on the S327 and S330 FireBox?
Every 2 years or as needed through Air Burners Technical Support.
152
What engine oil viscosity and crankcase capacity are required for the HATZ 4H50 engine in the S327 and S330 FireBox?
10W40 or 15W40 Diesel Grade (Ultra-Low Sulfur); oil capacity is 7.4 quarts (7.0 Liters).
153
What is the routine maintenance interval for engine oil, oil filter, and air filter elements on the S327 and S330 FireBox?
Initial service after the first 50 operating hours, then every 500 operating hours thereafter.
154
What patching compound is specified for repairing surface cracks in the refractory panels of the S327 and S330 FireBox?
Air Burners Part # 6900-1003 'Thermal-Ceramic Wet Pre-Mix' air-cured compound.
155
How long must the thermal-ceramic patching compound cure before the S327 or S330 FireBox can be returned to service?
Allow the patching material to harden overnight before firing the machine.
6
Section 6 · Questions 156–202
McPherson M30G Air Curtain Incinerator
47 questions
McPherson M30G Air Curtain Incinerator
156
Who is the manufacturer of the M30G Air Curtain Destructor?
McPherson Systems, Inc., located in Tifton, Georgia (phone: 229-386-2367).
157
What should be done with the operator's manual if the machine is sold?
The manual is considered a permanent part of the machine and should remain with the machine if sold.
158
What warning is given regarding operating the machine before reading the manual?
Caution: Read the Owner's Manual before operating the machine; do not start the machine unless you understand the instructions, as failure to do so could result in personal injury and/or equipment and property damage.
159
How does the McPherson Systems Air Curtain Destructor function?
It creates and maintains a uniform curtain of air across the top of the pit in which burning occurs, prohibiting smoke from escaping and increasing oxygen to the fire for faster and more complete combustion.
160
What are the typical operating temperatures inside the pit during burning?
Operating temperatures in the pit run between 1800°F and 2200°F.
161
Why are tractor or forklift tire stops not required for the refractory lined pit burner?
Because the pit is constructed above ground level.
162
What types of waste materials are designed to be burned in the destructor?
All non-treated wastes.
163
What weather conditions are considered unsuitable for operating the machine?
Rain, low clouds, or strong wind gusts are not suitable conditions for burning; the machine can only be operated properly when the weather is clear.
164
What action should be taken if sudden wind gusts occur during operation?
Stop loading the pit and allow the machine to continue operating until the existing fire has burned down.
165
What is the recommended trench length according to the M30G set-up diagram?
30 feet.
166
What is the recommended pit depth for the M30G setup?
10 feet or greater depth.
167
What is the standard width of the dirt trench for the M30G, and how can local law affect it?
The standard width is 9 feet, but it may be 8 feet in some areas depending on local laws.
168
From which location should material to be burned be loaded into the trench?
Material to be burned is loaded into the dirt trench from the side opposite the air manifold.
169
How full should a cold pit be loaded before ignition?
Load the pit 1/2 full with waste.
170
How much accelerant is used for initial lighting in a cold pit, and where should it be placed?
Douse the waste with 1 pint of fuel oil or diesel fuel, putting the majority of the oil on the waste at the front center side of the trench.
171
What types of ignition accelerants are strictly prohibited?
Highly volatile solvents such as mineral spirits, gasoline, etc., must not be used for ignition.
172
What regulatory check is advised before using accelerants?
Call your local EPA office for clarification, as some states do not allow the use of accelerants.
173
When should air from the fan first be introduced during a cold start?
Allow sufficient time for the fire to take hold before introducing any air from the air supply.
174
At what engine speed and duration should the unit run once the fan clutch is engaged after initial fire take-hold?
Increase engine speed to approximately 1100 RPM until ignition is uniform across the pit (usually 10 to 15 minutes).
175
What is the maximum height to which material can be loaded relative to the air curtain?
Ensure that no material protrudes above the air curtain when loading the pit.
176
What is the target engine operating speed during continuous burning?
Engine speed can be increased up to 2000 RPM.
177
What cold start steps can be omitted if hot coals remain from the previous day's burn?
Steps 2 and 3 (adding fuel oil/diesel and initial torch lighting) can be omitted.
178
How does starting a fire with existing coals differ regarding fan air introduction?
When lighting coals left from burning the previous day, it is necessary to introduce air from the fan before burning can start.
179
What must be done with the clutch lever before starting the diesel engine?
Disengage the clutch lever.
180
What engine condition must be met before the diesel engine will start?
The engine will start after the oil pressure level has risen to the proper operating level.
181
How is the fan clutch engaged on the unit?
Push the clutch lever forward/inward to engage the clutch.
182
How is engine throttle speed adjusted on the electronic control panel?
Using the throttle adjustment buttons: the up arrow increases throttle and the down arrow decreases throttle.
183
What is the contact phone number listed on the Flint Power Systems control panel?
1-800-821-4025.
184
What is the step-by-step procedure to shut down the diesel engine?
1. Disengage the clutch lever; 2. Reduce engine speed to 800 RPM; 3. Maintain 800 RPM for several minutes to allow the engine to cool; 4. Switch the ignition key to the OFF position.
185
How far in advance of shutdown should waste loading cease?
Stop loading the pit with material approximately 2 hours before shutdown is desired.
186
Why must the main fan keep running after loading stops during shutdown?
The main fan must remain running to allow remaining material in the pit to burn down completely.
187
When should the air supply be switched off during shutdown?
Turn off the air supply when the fire inside the pit has completely burned out.
188
What is the maximum allowable ash buildup in the pit?
Ashes should not build up higher than 1/3 of the pit depth or to the point where they impede combustion and blow out of the pit, whichever occurs first.
189
How should ashes be conditioned prior to removal from the pit?
Saturate the ashes with water for cooling and dust control.
190
How should excavated ashes be handled after removal to ensure total cooling?
Spread them out approximately 6 to 12 inches deep to allow total cooling before proper disposal.
191
Which components require daily lubrication?
The two (2) main fan bearings.
192
Which components require weekly lubrication?
The one (1) idler arm bushing and designated weekly drive points.
193
When should the door hinges be greased?
Hinges should be greased before the doors are opened.
194
What is the standard warranty period for the McPherson Systems pit burner?
One year, beginning from the date of sale of the pit burner by McPherson Systems, Inc.
195
What specific items are excluded from warranty coverage?
Drive belts and routine service items.
196
What are McPherson Systems' responsibilities under a warrantable failure?
McPherson Systems will furnish all parts and labor needed to repair damage resulting from a warrantable failure.
197
What must an owner do before the warranty expires to make a claim?
Notify McPherson Systems, Inc. of any warrantable failure and have the failure repaired by an official warranty facility.
198
Who is responsible for the cost of maintenance items replaced during warranty repairs?
The owner is responsible, unless such items are not reusable due to the warrantable failure.
199
Who pays for communication and freight costs related to warranty service?
The owner is responsible for communication expenses and similar costs; all warrantable items are F.O.B. Tifton, Georgia.
200
Does the warranty cover downtime, cargo damage, or incidental/consequential losses?
No, the owner is responsible for non-product repairs, downtime expenses, cargo damage, and all business costs; McPherson Systems is not responsible for incidental or consequential damages.
201
What condition voids the factory warranty?
The warranty is void and nonbinding if the product is determined to have been modified so as to alter its operating characteristics.
202
How are third-party components not manufactured by McPherson Systems warranted?
They are subject to the warranty terms imposed by the original manufacturer of each respective component.
7
Section 7 · Questions 203–250
M40E McPherson Systems Air Curtain Incinerator FAQ
48 questions
M40E McPherson Systems Air Curtain Incinerator FAQ
203
What is the model name and equipment type covered by this operator's manual?
M40E Waste Burner / Refractory Lined Pit Burner.
204
Who manufactures the M40E Waste Burner?
McPherson Systems, Inc., located in Tifton, Georgia.
205
What is the phone number and email address for McPherson Systems, Inc.?
Phone: (229) 386-2367; Email: mcsales@mcphersys.com.
206
What are the office hours for McPherson Systems, Inc. customer support?
8:00 A.M. to 5:00 P.M. EST, Monday through Friday.
207
What warning is given to operators prior to starting the M40E machine?
Caution: Read Owner's Manual before operation; do not start the machine unless you understand these instructions, as failure to read this manual could result in personal injury and/or equipment and property damage.
208
What should happen to the operator's manual if the M40E is sold?
This manual is a permanent part of the machine and should remain with the machine should you decide to sell it.
209
What is the operating principle of the M40E Refractory Lined Pit Burner?
It creates and maintains a uniform curtain of air across the top of a refractory lined pit in which burning is done, prohibiting smoke from leaving the pit and increasing burning efficiency by adding oxygen.
210
What are the typical operating temperatures inside the refractory lined pit during burning?
Operating temperatures in the pit run between 1800�F and 2200�F.
211
Why are tractor or forklift tire stops not needed for M40E operation?
Because the refractory lined pit is constructed above ground level.
212
What kind of waste materials is the machine designed to burn?
All non-treated wastes.
213
Under what weather conditions can the M40E machine be operated properly?
Only when the weather is clear; rain or low clouds are not suitable conditions for burning.
214
What should an operator do if wind gusts occur during burning operations?
Stop loading the pit and allow the machine to operate until the fire has burned down.
215
How full should the pit be loaded with waste before cold ignition?
Load the pit 1/2 full with waste.
216
How much accelerant is used for cold ignition, and where should it be poured?
Douse the waste with 1 pint of fuel oil or diesel fuel, putting the majority of the oil on the waste at the front center side of the pit.
217
What types of ignition fluids are strictly prohibited?
Do NOT use highly volatile solvents such as mineral spirits, gasoline, etc. for ignition.
218
What agency should be contacted regarding local restrictions on accelerants?
Call your local EPA office for clarification, as some states do not allow the use of accelerants.
219
When should the air supply fan be introduced during a cold start?
Allow sufficient time for the fire to take hold before introducing any air from the air supply.
220
At what fan speed should the fan initially be set as the fire grows in intensity?
Turn the fan on at approximately 1100 RPM until ignition is uniform across the pit (usually 10 to 15 minutes).
221
What restriction must be observed regarding material height when loading the pit?
Ensure that no material protrudes above the air curtain when loading the pit.
222
When is the air supply fan turned on fully during the loading sequence?
Turn on the air supply fan after the fire has ignited across the pit.
223
Under what condition can the accelerant and manual lighting steps be omitted during start-up?
Steps 2 & 3 can be omitted if the pit has enough coals remaining from burning the day before.
224
Why must the fan be started differently when relighting hot coals from the previous day?
It will be necessary to introduce air from the fan before burning can start.
225
How far in advance of the desired shutdown must pit loading stop?
Approximately 2 hours before shut down is desired, stop loading the pit with material.
226
Why must the air supply fan remain running during the shutdown process?
To ensure the air curtain remains active and allows the remaining material to burn down in the pit.
227
When should the air supply be turned off during shutdown?
Turn off the air supply when the fire inside the pit has completely burned out.
228
When is it safe to unload ashes from the pit?
Allow ashes to cool before unloading them from the pit.
229
Why is regular ash removal required?
Ash removal is required in order to maintain efficient and proper combustion.
230
What is the maximum permissible level of ash buildup in the pit?
Ashes should not be allowed to build up higher than 1/3 the pit depth, or to the point where they begin to impede combustion and blow out of the pit, whichever occurs first.
231
What preparation is required before removing ashes from the pit?
Ashes should be saturated with water for cooling and dust control before removal.
232
How deep should wet ashes be spread after removal to ensure complete cooling?
Spread them out approximately 6 to 12 inches deep to allow total cooling to take place before final disposal.
233
Which components on the M40E require daily greasing?
Main Fan Bearings (2 locations per fan), Underfire Blower (2 locations), and Midfire Blower (2 locations).
234
How many lubrication points are on the main fan bearings daily?
2 locations per fan.
235
How many lubrication points are on the underfire and midfire blowers daily?
2 points on the Underfire Blower and 2 points on the Midfire Blower.
236
Which components require weekly greasing on the M40E?
Idler arm bushing (1 per fan).
237
Which components require monthly greasing on the M40E?
Bottom doors (12 locations).
238
When should the door hinges be greased?
Hinges should be greased before the doors open.
239
What is the warranty coverage period for the M40E pit burner?
One year, beginning with the date of sale of the pit burner by McPherson Systems, Inc.
240
What failures are covered under the McPherson Systems warranty?
Any failure of the Product which results, under normal use and service, from a defect in material or workmanship (Warrantable Failure).
241
What items are explicitly excluded from warranty coverage?
Belts and service items are not covered by the warranty.
242
What are McPherson Systems' responsibilities during a warrantable failure?
McPherson Systems will furnish all parts and labor needed to repair the damage to the product resulting from the Warrantable Failure.
243
What are the owner's responsibilities for maintaining the warranty?
The owner is responsible for the operation and maintenance of the burner as specified in the operator's manual.
244
What procedure must the owner follow before the warranty expires to claim repairs?
The owner must notify McPherson Systems, Inc. of any Warrantable Failure and have the failure repaired by an official warranty facility.
245
What hours and phone number are available to locate official warranty service centers?
Call 1-229-386-2367 from 9:00 A.M. to 5:00 P.M. EST, Monday through Friday.
246
Who pays for maintenance items replaced during warranty repairs?
The owner is responsible for the cost of maintenance items replaced during warranty repairs, unless such items are not reusable due to Warrantable Failure.
247
Who is responsible for communication and freight expenses during a warranty claim?
The owner is responsible for communication expenses and similar costs; all warrantable items are F.O.B. Tifton, Georgia.
248
Is McPherson Systems, Inc. liable for downtime expenses, cargo damage, or incidental damages?
No; the owner is responsible for non-product repairs, downtime expenses, cargo damage, and all business costs and losses. McPherson Systems is not responsible for incidental or consequential damages.
249
What action voids the warranty on the M40E?
The warranty is void and nonbinding if, at the time of failure, the product is determined to have been modified so as to alter its operating characteristics.
250
How are components not manufactured by McPherson Systems warranted?
Components not manufactured by McPherson Systems, Inc. are subject to the warranty imposed by the manufacturer of that component.
8
Section 8 · Questions 251–320
Hatz 4H50TIC Engine FAQ
70 questions
Hatz 4H50TIC Engine FAQ
251
What type of engine is the Hatz 4H50TIC?
It is a liquid-cooled four-stroke diesel engine with direct injection. (Page 21, Paragraph 1 / Table 'Type')
252
How many cylinders does the Hatz 4H50TIC have?
The 4H50TIC has 4 cylinders. (Page 21, Paragraph 1 / Table 'Number of cylinders')
253
What are the bore and stroke dimensions of the 4H50TIC?
The bore is 84 mm and the stroke is 88 mm. (Page 21, Paragraph 1 / Table 'Bore/Stroke')
254
What is the total displacement of the 4H50TIC engine?
The displacement is 1.951 liters. (Page 21, Paragraph 1 / Table 'Displacement')
255
What is the normal operating engine oil pressure range for the 4H50TIC?
The oil pressure is 2.5 bar to 4.5 bar. (Page 21, Paragraph 1 / Table 'Engine oil pressure')
256
What is the direction/sense of rotation of the engine?
Left (counterclockwise), viewing toward the flywheel. (Page 21, Paragraph 1 / Table 'Sense of rotation')
257
How is the tappet / valve clearance adjusted on the 4H50TIC?
It features automatic hydraulic valve adjustment and is completely maintenance-free. (Page 21, Paragraph 1 / Table 'Tappet clearance')
258
What is the maximum permissible continuous tilt position of the 4H50TIC?
For HATZ cooler with integrated expansion tank: cooler low is 20°, other parts 30°. For HATZ cooler with external expansion tank: 30° continuous (or up to 40° for a maximum of 7 hours, after which the engine must be returned to horizontal and switched off for at least 5 minutes). (Page 21, Paragraph 1 & Footnotes 1-2)
259
What are the battery capacity requirements for the 4H50TIC?
12 V - 110 Ah / 760 A (EN) / 800 A (SAE), or 24 V - 66 Ah / 510 A (EN) / 540 A (SAE). (Page 21, Paragraph 1 / Table 'Battery capacity')
260
What does the abbreviation TIC designate in the model 4H50TIC?
TIC designates an engine equipped with a turbocharger, charge air cooling (intercooler), cooled exhaust gas recirculation (EGR), and diesel oxidation catalyst (DOC). (Page 22, Paragraph 1 / Table 'Engine specifications')
261
Does the 4H50TIC have a Diesel Particulate Filter (DPF)?
No, the 4H50TIC has a DOC and EGR, but does not include a DPF (the model with DPF is the TICD). (Page 22, Paragraph 1 / Table 'Engine specifications')
262
What is the engine oil capacity of the 4H50TIC during an oil change with filter?
Depending on the sump depth/contour: for h=118 mm it is 7.0 liters; for h=149 mm it is 7.3 liters; for h=148 mm it is 9.0 liters. (Page 22, Paragraph 2 / Table 'Engine oil capacities')
263
What is the difference in oil quantity between the MIN and MAX dipstick markings on the 4H50TIC?
The difference between MIN and MAX is 1.0 liter. (Page 22, Paragraph 2 / Table 'Engine oil capacities')
264
What is the coolant filling capacity for the 4H50TIC?
Approximately 13.7 liters with an external expansion tank, or 14.7 liters with an integrated expansion tank. (Page 23, Paragraph 1 / Table 'Coolant filling quantities')
265
What is the bare weight and equipped weight of the 4H50TIC engine?
Without operating fluids: 173 kg for standard engine (without cooler), 255 kg for OPU (Open Power Unit), and 354 kg for the Silent Pack version. (Page 23, Paragraph 2 / Table 'Weights')
266
What is the engine oil consumption limit for the 4H50TIC after the running-in period?
Max. 0.5% of fuel consumption, pertaining to full load. (Page 21, Paragraph 1 / Table 'Engine oil consumption')
267
What is the internal Hatz engine type number for the 4H50TIC?
The engine type number is 136. (Page 26, Paragraph 2 / Table 'Engine type number')
268
What is the tightening torque for the oil drain screw?
58 Nm. (Page 24, Paragraph 1 / Table 'Screw tightening torque')
269
What is the tightening torque for the engine cooler and charge air cooler drain screws?
50 Nm each. (Page 24, Paragraph 1 / Table 'Screw tightening torque')
270
What is the tightening torque for the protective guard screws (M10) on the TIC specification?
30 Nm. (Page 24, Paragraph 1 / Table 'Screw tightening torque')
271
What is the tightening torque for the screws on the breather cap of the crankcase ventilation?
4 Nm. (Page 24, Paragraph 1 / Table 'Screw tightening torque'; and Page 116, Step 6)
272
What oil quality specification is required for the 4H50TIC?
Because the 4H50TIC is equipped with a DOC, it requires 'low SAPS' oil meeting ACEA E6 or E8 (recommended), ACEA E9 or E11, ACEA C3/C4 (HTHS >= 3.5 mPas), or API CK-4 / CJ-4. (Page 27, Paragraph 1-2)
273
Why must 'low SAPS' engine oil be used in the 4H50TIC?
Unsuitable engine oil with higher sulfate ash, phosphor, and sulfur diminishes the functionality and service life of the catalytic converter (DOC). (Page 27, Paragraph 2, CAUTION box)
274
What engine oil viscosities are approved across operating temperature ranges?
0W/30 (-40°C to +30°C), 0W/40 (-40°C to +45°C), 5W/30 (-30°C to +30°C), 5W/40 (-30°C to +45°C), 10W/40 (-20°C to +45°C), and 15W/40 (-15°C to +40°C). (Page 27, Diagram 'Oil viscosity')
275
What is the recommended factory coolant for Hatz engines?
Mitan C12+ (5 liters container, Hatz order no. 0000 055 413 00). (Page 29, Paragraph 1 / Table 'Recommended cooler coolant')
276
What are the permissible mixing ratios of coolant fluid to water?
Min. 40 vol% coolant / 60 vol% water (frost-resistant to -24°C) to max. 50 vol% coolant / 50 vol% water (frost-resistant to -36°C). Exceeding 50 vol% degrades cooling action and frost protection. (Page 31, Paragraph 3 & Page 32, Table)
277
What water quality limits apply when mixing coolant concentrate?
Max. water hardness 20 °dGH (3.6 mmol/l), max. chloride content 100 ppm, max. sulfate content 100 ppm. Demineralized or distilled water is ideal. (Page 31, Paragraph 3 & Page 32, Table)
278
What types of diesel fuel are permitted for the 4H50TIC?
Europe: EN 590 or EN 15940 (paraffinic diesels: XTL, BTL, GTL, HVO, e-Fuels, CTL); UK: BS 2869 A1/A2; USA: ASTM D 975-09a 1-D S15 or 2-D S15 (Ultra Low Sulfur Diesel only); Japan: JIS K 2204 (max HFRR 520 um). (Page 32, Paragraph 2-3)
279
Can standard high-sulfur diesel be used in the 4H50TIC?
No. Engines equipped with DOC require Ultra Low Sulfur Diesel (e.g. S15) to prevent catalytic converter failure. (Page 25, Item 5 & Page 32, Paragraph 2)
280
What fuel should be used below 0°C?
Cold-resistant winter diesel fuel should be used for outside temperatures below 0°C to prevent fuel gelling/waxing. (Page 33, Paragraph 2)
281
Where is the engine type plate located on the 4H50TIC?
The engine type plate is affixed to the crankcase on the intake/starter side. (Page 25, Paragraph 1 & Page 36, Item 12)
282
How is the engine serial number broken down?
Position 1: Engine type number (e.g. 136); Position 2: Engine serial number; Position 3: Model year; Position 4: Consecutive fabrication number. (Page 26, Paragraph 1)
283
Where are the engine lifting eyes located and what rule applies when lifting?
They are attached at the top of the cylinder block/head (2 or 3 lifting eyes). All lifting eyes must always be used simultaneously with a hoist of sufficient capacity at a minimum chain/sling length of 780 mm. (Page 38, Item 1 & Pages 55, 57-58)
284
What electronic sensors and actuators are installed on the 4H50TIC?
Crankshaft speed sensor, air filter differential pressure sensor, rail pressure sensor, rail pressure control valve, EGR valve, coolant level sensor, coolant temperature sensor, charge air pressure and temperature sensor, camshaft sensor, low fuel pressure and fuel temperature sensor, water-in-fuel sensor, oil pressure and temperature sensor, metering unit on high-pressure pump, and ambient pressure sensor (in ECU). (Pages 43-45, Items 1-19)
285
What fuse ratings are used on the 4H50 central electrics board?
F1: Signal inputs for control unit (5 A); F2: Fuel pump (10 A); F3: Glow plugs (40 A); F4: Voltage supply for control unit (15 A); F5: Ignition terminal 15 (10 A); F6: Starter terminal 50 (30 A); F7: Ignition terminal 15 additional consumers (4 A); F8: Voltage converter on 24 V system (15 A). (Page 46, Table 'Central electrical system')
286
What minimum engine load is required during continuous operation?
Engine load must be maintained at at least 15% to avoid impairing running characteristics; prolonged zero/very low load must be followed by a brief period of higher load before shutoff. (Page 66, CAUTION box)
287
Is the use of starting fluid (e.g. ether) permitted on the 4H50TIC?
No. Starting fluid must never be used because uncontrolled ignition can cause severe engine damage. (Page 67, CAUTION box)
288
What is the maximum duration for a single starting attempt with the starter?
A starting attempt must last a maximum of 30 seconds. If the engine does not start, turn the key back to '0' and eliminate the cause. (Page 68, NOTICE box)
289
When does the pre-glow indicator light up on the Hatz Smart Panel?
It lights up at engine temperatures below 30°C. You should only start the engine after the indicator goes out. (Page 49, Table row 4)
290
What should the operator do before switching off the engine after operating at high load?
Allow the engine to idle / cool down for approximately 5 minutes at reduced speed and load to prevent damage from heat accumulation. (Page 70, CAUTION box)
291
What procedure must be followed when using a battery main disconnect switch?
Wait at least 30 seconds after switching the engine off before turning off the battery main switch, allowing the ECU time to save data and finish internal processes. (Page 71, NOTICE box)
292
What occurs when the engine goes into 'Emergency Operation' mode?
The available torque is reduced and the maximum speed is limited to 1900 rpm. The engine must only be run briefly to move the machine out of danger. (Page 50, Paragraph 2)
293
How is the fuel system vented/bled on the 4H50TIC?
Turn starting key to 'I' without starting; the electric fuel pump runs for approx. 30 seconds. Turn key to '0' and repeat this cycle several times until air is purged, then start the engine. (Page 63-64, Section 6.6)
294
Why must continuous-running engines be shut off for at least 30 seconds during refueling?
The ECU tests continuity of the water-in-fuel sensor wiring only on startup. Power cycling ensures the wiring and sensor are properly diagnosed. (Page 75, NOTICE box)
295
What checks must be carried out daily or every 8 to 15 operating hours?
Check engine oil level, check combustion air intake area, check cooler fins for contamination, and check the cooling system for proper level and leaks. (Page 83, Table 'Daily checks')
296
What maintenance tasks are required after the initial 50 operating hours of a new or rebuilt 4H50TIC?
Change engine oil and oil filter, and check all accessible screw connections for tightness. (Page 83, Table 'Initial service')
297
What is the routine maintenance interval for oil and fuel filter replacement?
Every 500 operating hours or at least every 12 months, whichever comes first. (Page 84, Table 'Routine service' & Footnote 2)
298
How often should the oil separator cartridge of the crankcase ventilation be replaced?
Every 500 operating hours or every 12 months. (Page 84, Table 'Routine service' & Page 115, Section 8.2.12)
299
How often should the poly v belt be checked and replaced on models with a three-phase alternator?
Checked every 500 operating hours / 12 months; replaced as necessary, but at the latest every 3,000 operating hours. (Page 84-85, Tables & Pages 104-108)
300
How often should the poly v belt be replaced on models without a three-phase alternator?
Every 4,000 operating hours. (Page 85, Table 'Routine service' & Page 114, Section 8.2.11)
301
What is the coolant replacement interval for the 4H50TIC?
Every 4 years. (Page 85, Table 'Routine service' & Page 125, Section 8.2.18)
302
How often must the EGR main radiator be cleaned on the 4H50TIC?
Every 4,000 operating hours (to be performed by trained technicians). (Page 85, Table 'Routine service' & Footnote 6)
303
How often must the charge air cooler (intercooler) be drained on the 4H50TIC?
Every 500 operating hours or every 12 months. (Page 84, Table 'Routine service' & Page 128, Section 8.2.19)
304
What are the factory vibration frequency setting values for the poly v belt tension?
New belt: 210 Hz (+10 Hz); belt after maintenance interval: 150 Hz (+10 Hz); minimum permissible tension: 125 Hz. (Page 107, Table 'Setting values for the belt tension')
305
What is the factory default password to reset the service interval indicator on the Hatz Smart Panel?
The default factory password is 2354. (Page 130, Step 4)
306
How should the primary air filter cartridge be serviced and how often must it be replaced?
Checked every 500 hours or when indicated; can be blown out with dry compressed air (max 5 bar) from inside out only once; must be replaced at least every 12 months. (Pages 84, 123-125, Section 8.2.17)
307
When must the secondary (safety) air filter cartridge be replaced?
It cannot be cleaned. It must be replaced after every 5th replacement of the primary filter, but no later than every 2 years. (Page 85, Footnote 4 & Page 124, Step 4)
308
What is the tightening torque for the plastic screw cap on the main fuel filter housing?
25 Nm. (Page 121, Diagram & Page 122, Step 10)
309
Why must main fuel filters always be installed dry without prefilling?
Fuel filters must be installed dry and not prefilled to prevent unfiltered contaminants and dirt particles from entering and damaging the high-pressure common rail injection system. (Page 120, CAUTION box)
310
How is water drained from the main fuel filter / water separator?
Place container under the drain socket, open drain screw (and vent screw if flow is slow) until clear diesel fuel emerges after water, then tighten screws. (Pages 116-117, Section 8.2.14)
311
Are cylinder head screws and injection system screws permitted to be retightened during maintenance?
No. Adjusting screws on the injection system are sealed with locking varnish and must not be touched, and cylinder head screws must not be retightened. (Page 116, Section 8.2.13, Safety note)
312
What do the diagnostic trouble code abbreviations SPN, FMI, and OC mean?
SPN = Suspect Parameter Number (error signal parameter); FMI = Failure Mode Identifier (error type); OC = Occurrence Count (error frequency). (Page 135, Paragraph 5)
313
What are the cable cross-section requirements when jump-starting (start support)?
For 12-volt systems: minimum 50 mm²; for 24-volt systems: minimum 35 mm². (Page 137, Paragraph 2, WARNING box)
314
What is the correct cable connection and disconnection sequence for jump starting?
Connection sequence: 1 (positive to discharged) -> 2 (positive to booster) -> 3 (negative to booster) -> 4 (negative to discharged). Disconnection sequence is the exact reverse: 4 -> 3 -> 2 -> 1. (Pages 138, 140, Steps 3 & 7)
315
Can a battery charger with a Boost fast-charge function be used as start support?
No. Do not use a charger unit with Boost function because electrical and ECU components could be destroyed by overvoltage. (Page 137, WARNING box)
316
What are common causes if the engine loses power/speed and emits black smoke?
Dirty air filter unit, faulty turbocharger or leaking intercooler/intake hoses, or malfunctioning fuel injectors. (Page 134, Table row 2)
317
What precautions must be observed during welding on the machine?
Disconnect the battery, connect the welding ground clamp as close as possible to the welding zone, and disconnect the plug connectors to the ECU and alternator voltage regulator. (Page 19, Paragraph 3)
318
What special fuel measure is required when storing the engine for 3 to 12 months?
Drain the tank until nearly empty, refill with FAME-free (biodiesel-free) diesel, and run the engine for a few minutes so only FAME-free fuel remains in the system. (Page 142, Step 1)
319
What are the permissible ambient storage conditions for the 4H50TIC?
Storage temperature between -25°C and +60°C, maximum relative humidity of 70%, and protected from direct sunlight. (Page 142, Paragraph 2)
320
Why might smoke appear briefly when a brand-new 4H50TIC is started for the very first time?
Exposed metal engine parts are factory coated with protective anti-corrosion wax that evaporates upon heating during initial startup. (Page 66, CAUTION box)
9
Section 9 · Questions 321–386
Size Specifications for Air Burners Incinerators FAQ
66 questions
Size Specifications for Air Burners Incinerators FAQ
321
What are the overall dimensions (L x W x H) of the S330 above-ground air curtain burner?
The overall size of the S330 is 40' 4" x 11' 10" x 9' 6".
322
What are the firebox dimensions (L x W x H) of the S330 air curtain burner?
The firebox dimensions for the S330 are 30' 2" x 8' 5" x 8' 1".
323
What is the total weight of the S330 air curtain burner?
The total weight of the S330 is 59,000 lbs..
324
What is the fuel consumption rate of the S330 air curtain burner in gallons per hour?
The fuel consumption rate of the S330 is 3.0 gal/hr..
325
What is the average throughput capacity of the S330 air curtain burner in tons per hour?
The average throughput capacity of the S330 is 11-13 tons/hr..
326
What are the complete technical specifications for the S330 above-ground air curtain burner?
For model S330: Overall Size: 40' 4" x 11' 10" x 9' 6"; Firebox Size: 30' 2" x 8' 5" x 8' 1"; Weight: 59,000 lbs.; Fuel Consumption: 3.0 gal/hr.; Average Throughput: 11-13 tons/hr..
327
What are the overall dimensions (L x W x H) of the S327 above-ground air curtain burner?
The overall size of the S327 is 37' 4" x 11' 10" x 9' 6".
328
What are the firebox dimensions (L x W x H) of the S327 air curtain burner?
The firebox dimensions for the S327 are 27' 2" x 8' 5" x 8' 1".
329
What is the total weight of the S327 air curtain burner?
The total weight of the S327 is 54,600 lbs..
330
What is the fuel consumption rate of the S327 air curtain burner in gallons per hour?
The fuel consumption rate of the S327 is 3.0 gal/hr..
331
What is the average throughput capacity of the S327 air curtain burner in tons per hour?
The average throughput capacity of the S327 is 9-11 tons/hr..
332
What are the complete technical specifications for the S327 above-ground air curtain burner?
For model S327: Overall Size: 37' 4" x 11' 10" x 9' 6"; Firebox Size: 27' 2" x 8' 5" x 8' 1"; Weight: 54,600 lbs.; Fuel Consumption: 3.0 gal/hr.; Average Throughput: 9-11 tons/hr..
333
What are the overall dimensions (L x W x H) of the S223 above-ground air curtain burner?
The overall size of the S223 is 33' 3" x 8' 6" x 8' 6".
334
What are the firebox dimensions (L x W x H) of the S223 air curtain burner?
The firebox dimensions for the S223 are 22' 11" x 6' 2" x 7' 1".
335
What is the total weight of the S223 air curtain burner?
The total weight of the S223 is 40,250 lbs..
336
What is the fuel consumption rate of the S223 air curtain burner in gallons per hour?
The fuel consumption rate of the S223 is 2.0 gal/hr..
337
What is the average throughput capacity of the S223 air curtain burner in tons per hour?
The average throughput capacity of the S223 is 7-9 tons/hr..
338
What are the complete technical specifications for the S223 above-ground air curtain burner?
For model S223: Overall Size: 33' 3" x 8' 6" x 8' 6"; Firebox Size: 22' 11" x 6' 2" x 7' 1"; Weight: 40,250 lbs.; Fuel Consumption: 2.0 gal/hr.; Average Throughput: 7-9 tons/hr..
339
What are the overall dimensions (L x W x H) of the S220 above-ground air curtain burner?
The overall size of the S220 is 30' 1" x 8' 6" x 8' 6".
340
What are the firebox dimensions (L x W x H) of the S220 air curtain burner?
The firebox dimensions for the S220 are 19' 8" x 6' 2" x 7' 1".
341
What is the total weight of the S220 air curtain burner?
The total weight of the S220 is 36,650 lbs..
342
What is the fuel consumption rate of the S220 air curtain burner in gallons per hour?
The fuel consumption rate of the S220 is 2.0 gal/hr..
343
What is the average throughput capacity of the S220 air curtain burner in tons per hour?
The average throughput capacity of the S220 is 5-7 tons/hr..
344
What are the complete technical specifications for the S220 above-ground air curtain burner?
For model S220: Overall Size: 30' 1" x 8' 6" x 8' 6"; Firebox Size: 19' 8" x 6' 2" x 7' 1"; Weight: 36,650 lbs.; Fuel Consumption: 2.0 gal/hr.; Average Throughput: 5-7 tons/hr..
345
What are the overall dimensions (L x W x H) of the S119 above-ground air curtain burner?
The overall size of the S119 is 27' 3" x 7' 2" x 7' 4".
346
What are the firebox dimensions (L x W x H) of the S119 air curtain burner?
The firebox dimensions for the S119 are 19' x 5' x 6'.
347
What is the total weight of the S119 air curtain burner?
The total weight of the S119 is 30,100 lbs..
348
What is the fuel consumption rate of the S119 air curtain burner in gallons per hour?
The fuel consumption rate of the S119 is 1.9 gal/hr..
349
What is the average throughput capacity of the S119 air curtain burner in tons per hour?
The average throughput capacity of the S119 is 3-5 tons/hr..
350
What are the complete technical specifications for the S119 above-ground air curtain burner?
For model S119: Overall Size: 27' 3" x 7' 2" x 7' 4"; Firebox Size: 19' x 5' x 6'; Weight: 30,100 lbs.; Fuel Consumption: 1.9 gal/hr.; Average Throughput: 3-5 tons/hr..
351
What are the overall dimensions (L x W x H) of the S119R** above-ground air curtain burner?
The overall size of the S119R** is 27' 6" x 7' 2" x 8' 3".
352
What are the firebox dimensions (L x W x H) of the S119R** air curtain burner?
The firebox dimensions for the S119R** are 19' x 5' x 6'.
353
What is the total weight of the S119R** air curtain burner?
The total weight of the S119R** is 39,900 lbs..
354
What is the fuel consumption rate of the S119R** air curtain burner in gallons per hour?
The fuel consumption rate of the S119R** is 1.9 gal/hr..
355
What is the average throughput capacity of the S119R** air curtain burner in tons per hour?
The average throughput capacity of the S119R** is 3-5 tons/hr..
356
What are the complete technical specifications for the S119R** above-ground air curtain burner?
For model S119R**: Overall Size: 27' 6" x 7' 2" x 8' 3"; Firebox Size: 19' x 5' x 6'; Weight: 39,900 lbs.; Fuel Consumption: 1.9 gal/hr.; Average Throughput: 3-5 tons/hr..
357
What are the overall dimensions (L x W x H) of the S116 above-ground air curtain burner?
The overall size of the S116 is 24' 7" x 7' 2" x 7' 4".
358
What are the firebox dimensions (L x W x H) of the S116 air curtain burner?
The firebox dimensions for the S116 are 16' x 5' x 6'.
359
What is the total weight of the S116 air curtain burner?
The total weight of the S116 is 27,500 lbs..
360
What is the fuel consumption rate of the S116 air curtain burner in gallons per hour?
The fuel consumption rate of the S116 is 1.9 gal/hr..
361
What is the average throughput capacity of the S116 air curtain burner in tons per hour?
The average throughput capacity of the S116 is 2-4 tons/hr..
362
What are the complete technical specifications for the S116 above-ground air curtain burner?
For model S116: Overall Size: 24' 7" x 7' 2" x 7' 4"; Firebox Size: 16' x 5' x 6'; Weight: 27,500 lbs.; Fuel Consumption: 1.9 gal/hr.; Average Throughput: 2-4 tons/hr..
363
What are the overall dimensions (L x W x H) of the S116R** above-ground air curtain burner?
The overall size of the S116R** is 24' 11" x 7' 2" x 8' 3".
364
What are the firebox dimensions (L x W x H) of the S116R** air curtain burner?
The firebox dimensions for the S116R** are 16' x 5' x 6'.
365
What is the total weight of the S116R** air curtain burner?
The total weight of the S116R** is 36,300 lbs..
366
What is the fuel consumption rate of the S116R** air curtain burner in gallons per hour?
The fuel consumption rate of the S116R** is 1.9 gal/hr..
367
What is the average throughput capacity of the S116R** air curtain burner in tons per hour?
The average throughput capacity of the S116R** is 2-4 tons/hr..
368
What are the complete technical specifications for the S116R** above-ground air curtain burner?
For model S116R**: Overall Size: 24' 11" x 7' 2" x 8' 3"; Firebox Size: 16' x 5' x 6'; Weight: 36,300 lbs.; Fuel Consumption: 1.9 gal/hr.; Average Throughput: 2-4 tons/hr..
369
What are the overall dimensions (L x W x H) of the T28 above-ground air curtain burner?
The overall size of the T28 is 17' 10" x 8' 5" x 5' 8".
370
What are the firebox dimensions (L x W x H) of the T28 air curtain burner?
The firebox dimensions for the T28 are 12' x 4' x 4'.
371
What is the total weight of the T28 air curtain burner?
The total weight of the T28 is 15,350 lbs..
372
What is the fuel consumption rate of the T28 air curtain burner in gallons per hour?
The fuel consumption rate of the T28 is 1.1 gal/hr..
373
What is the average throughput capacity of the T28 air curtain burner in tons per hour?
The average throughput capacity of the T28 is 1/2-1 tons/hr..
374
What are the complete technical specifications for the T28 above-ground air curtain burner?
For model T28: Overall Size: 17' 10" x 8' 5" x 5' 8"; Firebox Size: 12' x 4' x 4'; Weight: 15,350 lbs.; Fuel Consumption: 1.1 gal/hr.; Average Throughput: 1/2-1 tons/hr..
375
What are the overall dimensions (L x W x H) of the T26 above-ground air curtain burner?
The overall size of the T26 is 21' 8" x 7' 8" x 6' 8".
376
What are the firebox dimensions (L x W x H) of the T26 air curtain burner?
The firebox dimensions for the T26 are 12' x 4' x 4'.
377
What is the total weight of the T26 air curtain burner?
The total weight of the T26 is 17,500 lbs..
378
What is the fuel consumption rate of the T26 air curtain burner in gallons per hour?
The fuel consumption rate of the T26 is 1.1 gal/hr..
379
What is the average throughput capacity of the T26 air curtain burner in tons per hour?
The average throughput capacity of the T26 is 1/2-1 tons/hr..
380
What are the complete technical specifications for the T26 above-ground air curtain burner?
For model T26: Overall Size: 21' 8" x 7' 8" x 6' 8"; Firebox Size: 12' x 4' x 4'; Weight: 17,500 lbs.; Fuel Consumption: 1.1 gal/hr.; Average Throughput: 1/2-1 tons/hr..
381
What are the overall dimensions (L x W x H) of the T24 above-ground air curtain burner?
The overall size of the T24 is 19' 8" x 7' 8" x 5' 8".
382
What are the firebox dimensions (L x W x H) of the T24 air curtain burner?
The firebox dimensions for the T24 are 12' x 4' x 4'.
383
What is the total weight of the T24 air curtain burner?
The total weight of the T24 is 9,980 lbs..
384
What is the fuel consumption rate of the T24 air curtain burner in gallons per hour?
The fuel consumption rate of the T24 is 0.56 gal/hr..
385
What is the average throughput capacity of the T24 air curtain burner in tons per hour?
The average throughput capacity of the T24 is 1/2-1 tons/hr..
386
What are the complete technical specifications for the T24 above-ground air curtain burner?
For model T24: Overall Size: 19' 8" x 7' 8" x 5' 8"; Firebox Size: 12' x 4' x 4'; Weight: 9,980 lbs.; Fuel Consumption: 0.56 gal/hr.; Average Throughput: 1/2-1 tons/hr..
10
Section 10 · Questions 387–455
Kubota V3300
69 questions
Kubota V3300
387
Which Kubota engine models are covered in this workshop manual?
Kubota Diesel Engine models V3300-E2B (naturally aspirated) and V3300-T-E2B (turbocharged). (Page 153/Cover, Title; Page 155/To The Reader, Paragraph 1)
388
What does the 'E2B' designation signify in the Kubota V3300 engine model name?
E2B identifies engines designed to comply with Tier 2 / Phase 2 exhaust emission regulations, distinguishing them from earlier Tier 1 / Phase 1 engines. (Page 168/G-2, Section [2] 'E2B ENGINE', Paragraph 1-3)
389
Where is the engine model name and serial number located on the Kubota V3300?
It is stamped on the crankcase on the fuel injection pump side. (Page 167/G-1, Section [1], Diagram & Text)
390
How is the manufacturing date determined from the Kubota engine serial number?
The first character (number or letter) designates the year (e.g., 3=2003, 4=2004, D=2013), and the following letter designates the month and serial range (e.g., A=January for #0001-9999, B=January for #10000+). (Page 167-168/G-1 to G-2, Section [1], Tables & Example)
391
How are the cylinder numbers numbered on the Kubota V3300 engine?
Numbered No.1, No.2, No.3, and No.4 starting from the gear case (front) side towards the flywheel side. (Page 168/G-2, Section [3] 'CYLINDER NUMBER', Paragraph 1)
392
What is the firing order of the Kubota V3300 engine?
The firing order is 1-3-4-2. (Page 160/Specifications, Table row 'Firing Order')
393
What is the direction of engine rotation for the Kubota V3300?
Counter-clockwise when viewed from the flywheel side. (Page 160/Specifications, Table row 'Direction of Rotation')
394
What is the total displacement, bore, and stroke of the Kubota V3300 engine?
Bore x Stroke is 98 x 110 mm (3.86 x 4.33 in.), and total displacement is 3318 cm³ (202.53 cu.in.). (Page 160/Specifications, Table rows 'Bore x Stroke' and 'Total Displacement')
395
What are the SAE net continuous and intermittent power ratings for V3300-E2B and V3300-T-E2B?
V3300-E2B: Continuous 44.1 kW / 2600 rpm (59.1 HP), Intermittent 50.7 kW / 2600 rpm (68.0 HP). V3300-T-E2B: Continuous 53.8 kW / 2600 rpm (72.1 HP), Intermittent 61.9 kW / 2600 rpm (83.0 HP). (Page 160/Specifications, Table rows 'SAE Net Continuous' & 'SAE Net Intermittent')
396
What is the compression ratio of the V3300-E2B and V3300-T-E2B engines?
22.6 for the naturally aspirated V3300-E2B, and 21.8 for the turbocharged V3300-T-E2B. (Page 160/Specifications, Table row 'Compression Ratio')
397
What are the maximum and minimum bare idling speeds of the V3300 engine?
Maximum bare speed is 2800 rpm; minimum bare idling speed is 700 to 750 rpm. (Page 160/Specifications, Table rows 'Maximum' and 'Minimum Bare Idling Speed')
398
What is the dry weight of the Kubota V3300-E2B and V3300-T-E2B engines?
V3300-E2B weighs 241 kg (531 lbs); V3300-T-E2B weighs 250 kg (551 lbs). (Page 160/Specifications, Table row 'Weight (Dry)')
399
What are the overall dimensions (length, width, height) of the V3300-E2B and V3300-T-E2B?
V3300-E2B: Length 786.2 mm (30.95 in.), Width 563.5 mm (22.19 in.), Height 745 mm (29.33 in.). V3300-T-E2B: Length 786.2 mm (30.95 in.), Width 563.5 mm (22.19 in.), Height 793.2 mm (31.23 in.). (Page 163/Dimensions, Diagrams & Dimensions)
400
What combustion chamber design is used on the Kubota V3300 engine?
Spherical Type E-TVCS VERSION-II (Three-dimensional Environmental TVCS) with improved combustion surface at the top of the piston. (Page 160/Specifications, Table; Page 205/M-1, Para 2; Page 207/M-3, Section [4])
401
How many valves per cylinder does the Kubota V3300 engine have?
Three valves per cylinder: two intake valves with double ports and one exhaust valve. (Page 205/M-1, Para 2; Page 207/M-3, Section [3], Para 1)
402
What design features are employed on the cylinder block of the V3300?
Separate type crankcases: Crankcase 1 (hanger type containing combustion part) and Crankcase 2 (supporting Crankcase 1 and reducing noise). It is a linerless cylinder design for efficient cooling and wear resistance. (Page 206/M-2, Section [1], Para 1)
403
What is the purpose of the half-floating head cover on the V3300?
Rubber packing maintains the head cover approximately 0.5 mm off the cylinder head, dampening vibration and reducing noise coming from the cylinder head. (Page 206/M-2, Section [2], Para 1)
404
What type of piston rings are used on the Kubota V3300?
Top ring: nitrizing steel keystone ring; Second ring: chrome-plated peripheral undercut ring; Oil ring: chamfered contact faces with coil expander ring. (Page 207/M-3, Section [4], Para 3-4)
405
Why is a built-in dynamic balancer installed on the V3300 (balancer models)?
Four-cylinder engines produce secondary reciprocating inertia; the built-in balance shafts/weights absorb secondary inertia to reduce vibration. (Page 208/M-4, Section [5], Para 1-2)
406
How does the bottom bypass cooling system operate on the V3300?
When coolant temperature is low, the thermostat remains closed and coolant circulates through a bypass pipe. Once opening temperature is reached, the thermostat fully opens and closes off the bypass passage, forcing all coolant through the radiator. (Page 211/M-7, Section [2], Para 1-3)
407
What is the flow control thermostat and what problem does it eliminate?
It features a notched valve design to prevent coolant temperature hunting (severe cycles of overshoot and undershoot) by regulating coolant flowrate in small, smooth increments. (Page 210/M-6, Section [1], Para 1-4)
408
What type of fuel injection pump and governor does the Kubota V3300 use?
A Bosch type mini pump combined with a mechanical all-speed governor with a separate governor shaft that rotates at twice the speed of conventional shafts for rapid load response. (Page 160/Specifications, Table; Page 212/M-8, Section [1], Para 1-4)
409
What is the function of the boost compensator on the turbocharged V3300-T-E2B?
It senses turbocharger boost pressure to control fuel rack position, preventing fuel oversupply and transient black smoke during acceleration and low-boost operation. (Page 215/M-11, Section [1], Para 1-3)
410
What is the total lubricating oil capacity of the Kubota V3300 engine?
13.2 liters (3.49 U.S. gallons). (Page 160/Specifications, Table row 'Lubricating Oil Capacity'; Page 176/G-10, Table)
411
What API classification of engine oil is recommended for the V3300?
Class CF engine oil is recommended. Classes CD, CE, CF-4, and CG-4 can also be used depending on fuel sulfur content. (Page 160/Specifications, Table row 'Lubricating Oil'; Page 171/G-5, Table & Notes)
412
Which engine oil viscosity (SAE grade) should be selected based on ambient temperature?
Above 25°C (77°F): SAE30, SAE10W-30, or SAE10W-40. 0°C to 25°C (32°F to 77°F): SAE20, SAE10W-30, or SAE10W-40. Below 0°C (32°F): SAE10W, SAE10W-30, or SAE10W-40. (Page 176/G-10, Section 'Changing Engine Oil', Table)
413
What is the engine oil and oil filter change interval?
Initial change after 50 operating hours, then every 250 hours thereafter (or every 500 hours for filter cartridge under standard conditions). (Page 170/G-4, Maintenance Check List; Page 176/G-10; Page 177/G-11)
414
What is the factory specification and allowable limit for engine oil pressure?
At idle speed: factory specification / allowable limit is 49 kPa (0.5 kgf/cm², 7 psi). At rated speed: factory spec is 196 to 392 kPa (2.0 to 4.0 kgf/cm², 28 to 57 psi); allowable limit is 147.1 kPa (1.5 kgf/cm², 21.3 psi). (Page 228/S-10, Table 'LUBRICATING SYSTEM'; Page 234/S-16, Para 3)
415
What is the opening / working pressure of the engine oil pressure switch?
39.2 to 58.8 kPa (0.4 to 0.6 kgf/cm², 5.6 to 8.4 psi). (Page 228/S-10, Table 'LUBRICATING SYSTEM')
416
What is the relief valve cracking pressure in the lubrication system?
885 kPa (9.04 kgf/cm², 129 psi). (Page 228/S-10, Table 'LUBRICATING SYSTEM')
417
What are the thermostat valve opening and fully open temperatures?
Valve opening temperature: 74.5 to 78.5 °C (166.1 to 173.3 °F). Completely open temperature: 90 °C (194 °F). (Page 228/S-10, Table 'COOLING SYSTEM'; Page 235/S-17, Para 3-5)
418
What type and concentration of antifreeze should be used in the V3300?
Permanent Type (PT) long-life coolant (LLC). Mixing ratio must be less than 50% (40% protects to -24°C / -12°F; 50% protects to -34°C / -37°F). (Page 181/G-15, Section 'Anti-Freeze', Table & Notes)
419
What is the recommended fan belt deflection and checking procedure?
Deflection of 10.0 to 12.0 mm (0.394 to 0.472 in.) when pressed halfway between alternator and fan drive pulley at 98 N (10 kgf / 22 lbs). Checked every 250 hours. (Page 174/G-8, Section 'Fan Belt Tension'; Page 228/S-10; Page 234/S-16)
420
What pressure is used to test radiator water tightness and radiator cap leakage?
Radiator water tightness: test at 137 kPa (1.4 kgf/cm², 20 psi). Radiator cap air leakage: hold at 88 kPa (0.9 kgf/cm², 13 psi); pressure drop must not fall below 59 kPa (0.6 kgf/cm², 9 psi) in 10 seconds. (Page 228/S-10; Page 235-236/S-17 to S-18)
421
What type of fuel is specified for the Kubota V3300 engine?
Diesel Fuel No. 2-D (ASTM D975). (Page 160/Specifications, Table row 'Fuel')
422
What is the factory injection pressure for the V3300 fuel injection nozzle?
13.73 to 14.71 MPa (140 to 150 kgf/cm², 1991 to 2134 psi). (Page 160/Specifications, Table; Page 185/G-19; Page 229/S-11; Page 238/S-20)
423
How is the fuel injection nozzle opening pressure adjusted?
By changing the thickness of the adjusting washer inside the nozzle holder. A 0.01 mm (0.0004 in.) washer variation changes pressure by approx. 235 kPa (2.4 kgf/cm², 34 psi). (Page 185/G-19, Para 3 & Reference; Page 238/S-20)
424
How is injection nozzle valve seat tightness verified?
Apply 12.75 MPa (130 kgf/cm², 1849 psi) fuel pressure with a nozzle tester for 10 seconds; no fuel leakage should be observed. (Page 186/G-20, Para 2-3; Page 229/S-11; Page 239/S-21)
425
What is the factory fuel injection timing for V3300-E2B and V3300-T-E2B?
V3300-E2B: 0.20 to 0.22 rad (11.5° to 12.5°) before T.D.C. V3300-T-E2B: 0.11 to 0.13 rad (6.5° to 7.5°) before T.D.C. (Page 160/Specifications; Page 229/S-11; Page 237/S-19, Table)
426
How is the fuel system bled on the Kubota V3300?
Fill tank, loosen air vent coupling bolt on fuel filter until bubbles clear and retighten; open air vent cock on top of injection pump, run electric feed pump or crank engine for 10-15 seconds, then securely close the air vent cock. (Page 174/G-8, Section 'When bleeding fuel system')
427
How often should the fuel filter cartridge be replaced?
Every 500 operating hours. (Page 170/G-4, Maintenance Check List; Page 177/G-11, Section 'Replacing Fuel Filter Cartridge')
428
What is the cylinder compression pressure and allowable limit for V3300-E2B and V3300-T-E2B?
V3300-E2B: Factory spec is 4.32 MPa at 250 rpm (44 kgf/cm², 626 psi); allowable limit is 3.26 MPa at 250 rpm (33.2 kgf/cm², 472 psi). V3300-T-E2B: Factory spec is 3.92 MPa at 250 rpm (40 kgf/cm², 569 psi); allowable limit is 2.99 MPa at 250 rpm (30.5 kgf/cm², 434 psi). Cylinder variance must be <= 10%. (Page 223/S-5; Page 233/S-15)
429
What is the cold valve clearance specification for intake and exhaust valves?
0.23 to 0.27 mm (0.0091 to 0.0106 in.) for both intake and exhaust valves measured cold. (Page 179/G-13, Table 'Valve clearance'; Page 224/S-6)
430
What is the allowable limit for cylinder head surface flatness?
Allowable limit is 0.05 mm (0.0020 in.). (Page 223/S-5, Table 'ENGINE BODY')
431
What is the piston top clearance for V3300-E2B and V3300-T-E2B?
V3300-E2B: 0.72 to 0.90 mm (0.0283 to 0.0354 in.). V3300-T-E2B: 0.92 to 1.10 mm (0.0362 to 0.0433 in.). (Page 223/S-5, Table 'ENGINE BODY')
432
What are the standard cylinder bore diameter and oversize cylinder bore diameter?
Standard cylinder bore I.D.: 98.000 to 98.022 mm (3.8582 to 3.8591 in.), allowable limit 98.15 mm (3.8642 in.). Oversize bore I.D.: 98.500 to 98.522 mm (3.8780 to 3.8788 in.), allowable limit 98.65 mm (3.8839 in.). (Page 227/S-9, Table 'ENGINE BODY')
433
What is the crankshaft journal and crankpin diameter and their oil clearance limits?
Crankshaft journal O.D. is 74.977 to 74.990 mm (2.9518 to 2.9524 in.), oil clearance 0.018 to 0.062 mm (limit 0.20 mm). Crankpin O.D. is 52.977 to 52.990 mm (2.0857 to 2.0862 in.), oil clearance 0.018 to 0.051 mm (limit 0.20 mm). (Page 227/S-9, Table 'ENGINE BODY')
434
What are the factory specifications and allowable limits for piston ring end gap?
Compression ring 1 & 2: 0.30 to 0.45 mm (0.0118 to 0.0177 in.), allowable limit 1.25 mm (0.0492 in.). Oil ring: 0.25 to 0.45 mm (0.0098 to 0.0177 in.), allowable limit 1.25 mm (0.0492 in.). (Page 227/S-9, Table 'ENGINE BODY')
435
What is the allowable crankshaft side clearance (end play)?
Factory specification is 0.15 to 0.31 mm (0.0059 to 0.0122 in.); allowable limit is 0.50 mm (0.0197 in.). (Page 227/S-9, Table 'ENGINE BODY')
436
How is the proper replacement cylinder head gasket thickness selected?
By measuring average piston head protrusion or recess from the cylinder block deck with a dial indicator. Gaskets are identified by notch code: 2 notches (0.80 mm compressed), 1 notch (0.90 mm compressed), or without notch (0.95 mm compressed). (Page 249/S-31, Table 'Selecting the Cylinder Head Gasket')
437
What is the tightening torque for the cylinder head screws on the Kubota V3300?
98.1 to 107.9 N-m (10.0 to 11.0 kgf-m, 72.3 to 79.6 ft-lbs). Apply engine oil to threads and seating faces before tightening. (Page 231/S-13, Table [2]; Page 248/S-30)
438
What is the tightening torque for the connecting rod cap screws?
78.5 to 83.4 N-m (8.0 to 8.5 kgf-m, 57.9 to 61.5 ft-lbs). Apply engine oil to threads and seating faces. (Page 231/S-13, Table [2])
439
What is the tightening torque for the flywheel mounting screws?
98.1 to 107.9 N-m (10.0 to 11.0 kgf-m, 72.3 to 79.6 ft-lbs). Apply engine oil to threads and seating faces. (Page 231/S-13, Table [2])
440
What is the tightening torque for the crankshaft center bolt (crankshaft screw)?
255.0 to 274.6 N-m (26.0 to 28.0 kgf-m, 188.1 to 202.5 ft-lbs). Apply engine oil to threads and seating face. (Page 231/S-13, Table [2])
441
What is the tightening torque for the main bearing case screws?
137.3 to 147.1 N-m (14.0 to 15.0 kgf-m, 101.3 to 108.5 ft-lbs). Apply engine oil to threads and seats. (Page 231/S-13, Table [2])
442
What is the tightening torque for the fuel injection nozzle holder assembly?
49.0 to 68.6 N-m (5.0 to 7.0 kgf-m, 36.2 to 50.6 ft-lbs). (Page 231/S-13, Table [2]; Page 246/S-28)
443
What is the tightening torque for the glow plugs on the V3300?
19.6 to 24.5 N-m (2.0 to 2.5 kgf-m, 14.5 to 18.1 ft-lbs). (Page 231/S-13, Table [2]; Page 242/S-24)
444
What is the tightening torque for the rocker arm bracket screws?
49.0 to 55.9 N-m (5.0 to 5.7 kgf-m, 36.2 to 41.2 ft-lbs). (Page 231/S-13, Table [2]; Page 247/S-29)
445
What starter motor and battery ratings are standard on the Kubota V3300?
Starter: 12 V, 2.5 kW electric starting motor. Battery: 12 V, 112 AH. Charging alternator/dynamo: 12 V, 540 W. (Page 160/Specifications, Table rows 'Starting System', 'Battery', 'Dynamo for Charging')
446
What is the internal resistance of each glow plug on the Kubota V3300?
Approximately 1.0 ohm. (Page 229/S-11, Table 'ELECTRICAL SYSTEM'; Page 242/S-24, Section 'Glow Plug')
447
How do you test the dual-coil engine stop solenoid on the V3300?
Connect pulling coil (P terminal) and holding coil (H terminal) through separate switches to battery positive, with body grounded. When energized, plunger must pull in; holding coil keeps plunger in after pulling coil is deactivated. Never apply pulling current for longer than 2 seconds. (Page 242/S-24, Section 'Engine Stop Solenoid', Para 1-7 & IMPORTANT box)
448
What are the wear limits for starter brushes and commutator diameter?
Starter brush length: factory spec 18 mm (0.7086 in.), allowable limit 11 mm (0.4331 in.). Commutator O.D.: factory spec 32 mm (1.2598 in.), allowable limit 31.4 mm (1.2362 in.). Mica undercut limit: 0.2 mm (0.0079 in.). (Page 229/S-11, Table 'ELECTRICAL SYSTEM')
449
What specific gravity indicates a fully charged Kubota battery at 20°C (68°F)?
1.260 Sp.Gr. indicates 100% charged (1.230 = 75%, 1.200 = 50%, 1.110 = discharged). Recharge or replace if below 1.215 or if cells differ by more than 0.05. (Page 183/G-17; Page 240/S-22, Table 'Specific Gravity')
450
What are the probable causes if a Kubota V3300 engine produces black or dark gray exhaust smoke?
Engine overload, low grade fuel, clogged fuel filter, clogged air cleaner, or deficient nozzle injection. (Page 220/S-2, Table 'TROUBLESHOOTING')
451
What causes white or blue exhaust smoke on the V3300 engine?
Excessive engine oil in the crankcase, worn or stuck piston rings/cylinder, incorrect injection timing, clogged turbocharger waste oil pipe, or faulty turbocharger seal. (Page 220/S-2, Table 'TROUBLESHOOTING')
452
What causes fuel to mix into engine lubricating oil?
Oil dilution from defective seals/packing, worn injection pump plunger, defective injection nozzle, or broken injection pump body. (Page 221/S-3, Table 'TROUBLESHOOTING')
453
What critical precaution must be taken before removing the fuel injection pump unit?
Set No.4 piston to TDC compression, lock flywheel, lock the fuel camshaft by tightening upper and lower dog-point lock screws against the shaft without over-torquing, and scribe gear mesh align marks on idle gear 2. (Page 252/S-34, Section '(6) Injection Pump Unit', Steps 1-5)
454
How is the nozzle heat seal removed from the cylinder head?
Lightly drive a Phillips screwdriver (approx. 6 mm / 1/4 in. diameter) into the heat seal hole, turn 3-4 times each way, and pull the heat seal out together with the copper gasket. Always replace heat seal and gasket with new ones. (Page 246/S-28, Section 'Nozzle Heat Seal Service Removal Procedure', Steps 1-3)
455
In what orientation must the cooling fan be installed on the V3300?
Attach the cooling fan with its '1C010' marking facing frontward towards the radiator. (Page 245/S-27, Section 'Air Cleaner, Muffler and Others', IMPORTANT box)