OVERVIEW
Air Burners’ PGF-1000 is a revolutionary new method for eliminating wood and other vegetative waste, as well as clean construction debris. At the core of the system is Air Burners’ patented FireBox technology which has been tested and approved by regulatory agencies around the globe. The PG FireBox can eliminate up to 20 tons per hour [18.2 mt/h] of waste material while simultaneously producing up to 1000 kW of clean, emission-free energy without the use of supplemental fossil fuels.
In addition, the PG FireBox does not require any of the costly and emissions-intensive pre-processing (grinding/chipping/sorting) of fuel required by conventional biomass power generating systems. The PG FireBox consumes whole logs, limited only by the length of the FireBox in the system (generally 27 ft [8.2 m]). The volume of the waste material is reduced by approximately 98%, leaving only a small quantity of ash and biochar that can be repurposed for agricultural or other uses.
A portion of the ‘waste’ heat in the exhaust from the FireBox is captured and directed to a heat exchanger to heat a thermal oil, which in turn supplies an Organic Rankine Cycle (ORC) power generating unit. The ORC utilizes an organic working fluid in a ‘reverse refrigeration process’ where the thermal energy input to the system is converted to electrical energy by driving an asynchronous (induction) generator. The system is connected to the local electrical grid in accordance with local regulations where either some or all of the energy is consumed on site and any excess energy produced is sold back to the utility.
Aside from the electrical grid connection, only a cooling source for the ORC is required at the site. This can be either air-cooling or water cooling. In the case of water cooling no water is consumed or contami
Specifications for Power Generation module
POWER REQUIREMENTS
480 VAC/60 Hz/3φ or 400 VAC/50 Hz/3φ, 2.25 kA Service
Higher Voltages Available
POWER FACTOR
Load and site-dependent (0.9 – 1.0)
POWER GENERATION MODULE
Fully-Integrated Organic Rankine Cycle (ORC) Power Module with 1000 kW Asynchronous Generator
SAFETY SYSTEMS
Electrical Grid Protection
Over-Temperature
Over-Pressure
CONTROL SYSTEM
PLC-Based; Remote Monitoring and Control over the Internet
TRANSPORTATION AND SETUP
Ships in containers; Ready for immediate use after simple skid alignmment and hood installation; Lifting eyes provided for crane lifting. Skid bases facilitate final positioning
COOLING WATER (CW) REQUIREMENTS
1450 gpm [91.5 l/s], 77° F [25° C] Max.
CW INTERFACE
DN250 PN16 Flanges
INDUCTION FAN
VFD-Controlled; Variable Speed
HOT OIL (HO) PUMP
VFD-Controlled; Variable Speed
HO SYSTEM THERMAL FLUID
Theminol 66 (or equiv.)
CONSTRUCTION
Steel WF beam and square tubing construction with full-length skid plate; Epoxy-paint
WEIGHT
118,500 lbs [53900 kg]
DIMENSIONS
L x W x H
See Site Plan Drawing
Specifications for Firebox Module
AIR CURTAIN FAN POWER
30 hp [22 kW] Electric Motor
VFD-Controlled
BURN CONTAINER (FIREBOX)
4″ [102 mm] thick refractory panels filled with proprietary thermal ceramic material. Two full-height rear doors, two ignition holes
SAFETY SYSTEMS
Fully integrated with PGF controller
INSTRUMENT PANEL
Touch-screen control from PGF Control Room
AIR CURTAIN FAN MOTOR CONTROL SYSTEM
PLC-Based; Speed selection fully integrated with system controller
AIR SUPPLY
Custom Heavy Duty Fan
TRANSPORTATION AND SETUP
Shipped fully assembled and tested, requires only connection of the three-phase motor power to the PG Module power distribution panel
WASTE MATERIAL ELIMINATION RATE
Up to 10 tons per hour
[9.1 mt/h]
FIREBOX MODULE WEIGHT
32,500 lbs [14800 kg]
OVERALL DIMENSIONS
L x W x H
30′ 2″ x 7′ 5″ x 8′ 6″
[9.2 m x 2.3 m x 2.6 m]
FIREBOX INSIDE DIMENSIONS
L x W x H
19′ 8″ x 5′ 0″ x 7′ 1″
[6.0 m x 1.5 m x 2.2 m]
Specifications for AIR BURNERS AIR BLAST COOLER FOR CONDENSING WATER
8,100 lbs [3680 kg]